Recent content by 123456

  1. 1

    Enable/Disable "Notify Surveillance Center" via ISAPI

    To be clear... I close the contact when the alarm is armed, not activated. This way, with "combined alarm," if the camera detects an intrusion, it should send a notification. However, if the alarm is disarmed, the contact is open, even if the camera detects an intrusion, it won't send a...
  2. 1

    Enable/Disable "Notify Surveillance Center" via ISAPI

    Hi, and thanks for your support. As I wrote in the previous post, I tried activating the "combined alarm" with the intrusion event camera, but it didn't work. You can also try closing the contact as I did in the first photo and setting the "combined alarm" with a camera. If it works for me, the...
  3. 1

    Enable/Disable "Notify Surveillance Center" via ISAPI

    I've done some tests, and the "combined alarm" doesn't seem to work: Without configuring the "combined alarm," when contact 1 closes, I receive a notification and a buzzer. If I add the "combined alarm" camera with "intrusion," I receive no notification or buzzer when contact 1 is closed and...
  4. 1

    Enable/Disable "Notify Surveillance Center" via ISAPI

    I think if I connect an output of my alarm to activate an "alarm input" in the NVR this sends the notification when the alarm input becomes NO or NC but it does not enable\disable the "Notify Surveillance Center" function in the linkage method of the camera in the NVR
  5. 1

    Enable/Disable "Notify Surveillance Center" via ISAPI

    To reproduce the problem: I tested on a DS-7616NI-M2 with Firmware Version V5.04.066 build 250620 For example, go to the camera settings and set the sensitivity to 71; it was previously 70, and save it. Now go to the NVR, "Linkage Method," enable or disable "Notify Surveillance Center," and...
  6. 1

    Enable/Disable "Notify Surveillance Center" via ISAPI

    Maybe I didn't understand how "Alarm Input" works. If I close the contact, it simply communicates to "Notify Surveillance Center" that the contact has been closed, but how does it send notifications from the cameras?
  7. 1

    Enable/Disable "Notify Surveillance Center" via ISAPI

    I have always enabled "Notify Surveillance Center" on the cameras because otherwise it doesn't mark intrusion detect on the recording timeline. While I want to automate Enable/Disable "Notify Surveillance Center" on nvr to notify me on HikConnet app only when I have armed my alarm system
  8. 1

    Enable/Disable "Notify Surveillance Center" via ISAPI

    I'll do further checks. What's your NVR and firmware? Thanks for the support.
  9. 1

    Enable/Disable "Notify Surveillance Center" via ISAPI

    No, By changing "Linkage Method" on NVR, "Area Settings" is also overwritten, perhaps because even if it is part of a different tab, the page is saved only once. Yes, the camera is newer than the NVR Device Model DS-2CD2387G2H-LISU/SL Firmware Version V5.7.17 build 240606
  10. 1

    Enable/Disable "Notify Surveillance Center" via ISAPI

    NVR Device Model DS-7608NXI-I2 / 8P/S Firmware Version V4.62.225 build 240123 for enable enable Notify Surveillance Center send HTTP PUT .... <?xml version "1.0" encoding="UTF-8"?> <EventTrigger> <id>fielddetection-4 </id> <eventType>fielddetection </eventType>...
  11. 1

    Enable/Disable "Notify Surveillance Center" via ISAPI

    Thanks for your help. After your help, for camera setting I used the browser developer mode to select "Network" and then "Payload." I was able to see the code I needed to insert to enable and disable the various links. Now the problem is if I activate "Notify Surveillance Center" from the NVR...
  12. 1

    Enable/Disable "Notify Surveillance Center" via ISAPI

    Hi all, I'm interested too, but I can't find the HTTP command:
  13. 1

    Hikvision Permanent Region Change

    I can transfer only the mtdblock2 with serial TTL cable?
  14. 1

    Hikvision FIRMWARE TOOLS - change language, extract files and create own firmware

    the latest firmware can not be taken via serial cable?
  15. 1

    HikVision DS-7608NI-E2/8P - Motion detection - Event

    you can use VCA function in playback remote in pc software ivms4200 https://www.ipcamtalk.com/showthread.php/6248-NVR-DS-7608NI-ST-Intelligent-video-analytics