The new 8003(B) its faster without lags.And working realy well.BUT the camera lens it is not so good at low light conditions and is loosing very much at angle.I reale having trubles because i use The old as secondary intercom and it is realy lagy.
For this 2 cameras use as trigger from onvif of cameras with a door contact and pir conected to cameras.From the time that door open or trigger from pir take 5-6 sec to see person at the camera.So i play with the number of images for proccesing.Normal must have 6-7sec but i am try to find the...
Yes i have also tried this. And geting 15 out 20. At start was thought that was the pre trigger buffer that i had 7sec and thinking that the BI starting to count images for analyse at the moment that starting the pre trigger. I set the buffer to 2 sec but having same problem.
When analyzing with right clicking getting Normal answer as person detected.
At 20 triggers 5 going DeepStack: Alert cancelled (nothing found) . Not all.
With last update 5.4.5.1 have continued the missing alerts.I see the log and gives DeepStack: Alert cancelled (nothing found) . I have test 20 images for analysing but have the same problem. For this reason i am runnig paralel the AI tool to compare the alerts.I thing is BI issue.
I try to update at last version and getting this error. AITool-VorlonCD-v2.0.988 no such table: History [SQLiteException] (In ) (UpdateHistoryList) is it known for anyone?
With this version getting an error..
tryied the versions 2.0.522.7681 and 2.0.526 when i open the new setting tab and setting up the url i get error :
Deepstack returned 'Invalid value for min_confidence' - http status code 'BadRequest' (400) in 38ms: Bad Request.
... AI URL for 'DeepStack'...
Ah ok.Then you can just add enother button without use the display but ,which burglar take a time to do this.It is more easy to just to brake in the door.
At the manual says support IEEE 802.3af .That is mean can work ok with 4 wires.But i dont know how logg and if can be used for live streaming (RTSP). With one KD8003 + 3 modules need 5-6Watt with live streame enabled at 720p. You can test it and say if it worked.
I wish to all have a Happy new...
I know the wiring and that what you say it is the right.It is INPUT...But we have testing as demo one 8003 module with this type of connection and working without problem for the last 6 months.This is only a backup extreme solution.When i make a job for me is a must the extra 12 or 24 volt...
No . You are using all 8 cat 7 for the Modul. And After that the Modul have a 12v output that using for your door.If you want send pm.
Gesendet von iPhone mit Tapatalk
A ok.I just read it.I am not sure if it works because if there is inside the module wired with B alternative then you need all 8 wires.If it is with A then you need all wiring to your swich running in A and then can be work.I will make a test with my demo display and see if working.I have not...
You need this device DS-KAD706-S to connect DS-KD8003-IME2 .And after that you can choose if you want a 2 wire display or ethernet.I have not test it to use only the 4 wires but i dont think it works.And yes using poe. With this model DS-KD8003-IME2 you dont use lan jack.
There are 2 versions of hikvision
DS-KD8003-IME1 need normal poe with all 8 wires(but have 12v output)
DS-KD8003-IME2 need only 2 wires but you need extra device for this version to comunicate with this 2 wires.