katnelson7175's latest activity

  • K
    katnelson7175 replied to the thread Alarm Output Rating.
    Here's another solution to the CTRL P (Normally Closed Relay) Disregard the load illustration above for the photo sensor output....use...
    • 1733790425856.png
    • 1733790579376.png
    • 1733806773912.jpeg
  • K
    katnelson7175 replied to the thread Alarm Output Rating.
    So what you do is: get a 12v female barrel plug pigtail. Tin your red wire on the pigtail. snip it off a little bit snip your zener...
    • IMG_20241019_084511.jpg
  • K
    katnelson7175 replied to the thread Alarm Output Rating.
    No1 and C1 = Alarm 1 CTRL and P = Alarm 2 What happens if you take a multi tester that's capable and touch both leads to a piece of...
    • Alarm_Block.jpg
    • Wiring_with_Zener_diode.jpg
  • K
    katnelson7175 replied to the thread Amcrest NV4232E-16P-EI.
    Removed the pluggable block for NO1 C1 GND 1 2 GND and tested on GND with my multitester (-) lead and (+) lead to P It is confirmed...
  • K
    katnelson7175 replied to the thread Amcrest NV4232E-16P-EI.
    https://ipcamtalk.com/threads/alarm-output-rating.71447/ In manual it says CTRL is "Controllable 12 V power output. It is to control...
    • 1729145597624.png
  • K
    My alarm block looks like this: NO1 C1 GND 1 2 GND CTRL P GND 3 4 GND My current setup is 12v 1 amp power supply (+) to...
    • Alarm_Block.jpg